Proxmox - Erreur Device Mismatch detected
Sur un stockage, j’ai l’erreur suivante :
root@pve11:~# pvs WARNING: Device mismatch detected for datastore-pve13/thinpool-datastore-pve13_tmeta which is accessing /dev/sdd instead of /dev/mapper/pve13. WARNING: Device mismatch detected for datastore-pve13/thinpool-datastore-pve13_tdata which is accessing /dev/sdd instead of /dev/mapper/pve13. WARNING: Device mismatch detected for datastore-pve12/thinpool-datastore-pve12_tmeta which is accessing /dev/sdc instead of /dev/mapper/pve12. WARNING: Device mismatch detected for datastore-pve12/thinpool-datastore-pve12_tdata which is accessing /dev/sdc instead of /dev/mapper/pve12.Sauvegarde du fichier lvm.conf
cp /etc/lvm/lvm.conf /etc/lvm/lvm.conf.bak.$(date +%F)Remplacer le bloc Devices par :
devices { obtain_device_list_from_udev = 1 preferred_names = [ "^/dev/mapper/", "^/dev/dm-[0-9]+$" ]
# On SCANNE uniquement ces PV (adapte si un nom change un jour) filter = [ "a|^/dev/mapper/pve11$|", "a|^/dev/mapper/pve12$|", "a|^/dev/mapper/pve13$|", "a|^/dev/mapper/pve-profs$|", "a|^/dev/nvme0n1p3$|", # PV local du VG 'pve' "r|.*|" ]